Operation Manual ServoOne Supply Unit
79
ID no.: 1101.21B.6-00 Date:04/2020
A.3 Pre-assembled connection cables
For devices of size BG5, pre-assembled connection cables are available for the DC link
coupling. For devices of sizes BG6a and BG7, connection cables must be specied by
the customer. Dene the cable cross-section according to local regulations and condi-
tions. It is dependent on the cable protection, the type of cable laying and the ambient
temperature.
Type L Cross-section Model Connection
DC link
BG5
193mm 20mm²
Flat copper braid
covered with double
heatshrink sleeve
Flat lug with hole
Ø5.5mm on both
ends
Sketch
L
4
15
Table A.11 Technical data, pre-assembled connection cables
A.2 Current required for the control supply
Size BG5 BG6a BG7
Device
SO84.040
SO84.076
SO84.115
SO84.170
SO84.375
SO84.540
Terminal X9, X10 X44
Wall mounting
Typ. starting current 7A 10A -
Continuous current 2.5A 8A -
Liquid cooling
Typ. starting current 7A 8A 4A
Continuous current 2A 2A 2A
Table A.10 Current required for the control supply