Operation Manual ServoOne Supply Unit
66
ID no.: 1101.21B.6-00 Date:04/2020
The following functions and displays are available:
y Indication of the device status (see chap.6.1, p.71)
The device status is indicated after switching on the control supply. If no input
is made via the keypad for 60seconds, the display switches back to the
indication of the device status.
y Indication of the device error status (see chap.6.1.1, p.71)
On the occurrence of an error in the device, the display is immediately switched
to the indication of the error code.
y Parameter setting (indication "PA") (see chap.5.4.3, p.68)
Resetting device parameters to their factory setting
y Ethernet IP address setting (indication "IP") (see chap.5.4.4, p.68)
Ethernet IP address and subnet mask setting
y Field bus settings (indication "Fb") (see chap.5.4.5, p.69)
E.g. eld bus address setting
5.4 Integrated control unit
The integrated control unit permits diagnostics on the drive controller. . The control unit
comprises the following elements, all located on the front of the device:
y 2-digit 7-segment display (D1, D2)
y Two buttons (T1, T2)
D1
D2
T2
T1
Figure 5.7 Integrated control unit