Operation Manual ServoOne Supply Unit
68
ID no.: 1101.21B.6-00 Date:04/2020
5.4.4 Ethernet IP address menu (IP)
An Ethernet TCP/IP port is available as a service and diagnostics interface. The IP
address is set in the factory to 192.168.39.5. It can be changed using the PC software
DriveManager5 or via the display.
Menu level
Param-
eter
Value
range
Meaning Explanation
1 2
IP Iu b0 00..FF
IP address
update byte0
Setting for byte0 of the IP address
in hexadecimal format (e.g. "05" in
192.168.39.5)
b1 00..FF
IP address
update byte1
Setting for byte1 of the IP address
in hexadecimal format (e.g. "27" in
192.168.39.5)
b2 00..FF
IP address
update byte2
Setting for byte2 of the IP address
in hexadecimal format (e.g. "A8" in
192.168.39.5)
b3 00..FF
IP address
update byte3
Setting for byte3 of the IP address
in hexadecimal format (e.g. "C0" in
192.168.39.5)
Ir - -
IP reset to
factory setting
Reset IP address to factory setting
(192.168.39.5)
Su b0 00..FF
Subnet mask
update byte0
Setting for byte0 of the subnet mask
in hexadecimal format (e.g. "00" in
255.255.255.0)
b1 00..FF
Subnet mask
update byte1
Setting for byte1 of the subnet mask
in hexadecimal format (e.g. "FF" in
255.255.255.0)
b2 00..FF
Subnet mask
update byte2
Setting for byte2 of the subnet mask
in hexadecimal format (e.g. "FF" in
255.255.255.0)
b3 00..FF
Subnet mask
update byte3
Setting for byte3 of the subnet mask
in hexadecimal format (e.g. "FF" in
255.255.255.0)
Sr - -
Subnet mask
reset to factory
setting
Reset subnet mask to factory setting
(255.255.255.0)
Table 5.9 IP address menu
5.4.3 Parameter menu (PA)
The following functions are available on the Parameter menu:
y Reset device to factory settings
Menu level
Parameter
Value
range
Meaning Explanation
1 2
PA Pr - - Parameterreset Resetdevicesettingstofactorysettings.
Table 5.7 Parameter menu
Error messages displayed during user data entry
A failed user action is indicated by an error message. The message consists of the
alternating display of "Er" and the error number.
NOTE:
The error messages displayed during user data entry should not be confused
with drive error messages. You will nd detailed information on the error codes
and on error management in the device help.
Error number Meaning
00 File system no error
01 File system any le system error
02 File system command rejected
03 File system function parameter invalid
04 File system create le error
05 File system open le error
17 Parameter reset to factory settings failed
18 Parameter write access failed
19 Save parameter data set non volatile failed
20 Not all parameters written
21 Error while reset to factory settings
Table 5.8 Error messages displayed during user data entry