72
ID no.: 1101.21B.6-00 Date:04/2020
Error
number
Error
location
Error text
06 Overtemperature PTC
00 Unknown error
01 PTC temp. to high
02 PTC DIN2 error detected (shortcut, resistance smaller 50Ohm)
03
PTC DIN3 error detected (overtemperature, resistance higher than
3500Ohm)
04
PTC DIN1 error detected (hysteresis after over temperature, resistance
higher than 1650Ohm)
07 Overtemperature powerstage cooler
00 Unknown error
01 Overtemperature inverter detected
08 Overtemperature PSU interior
00 Unknown error
01 Overtemperature PSU interior detected
09 Error grid
00 Unknown grid error
01 Grid frequency out of range
02 Grid voltage out of range
03 Timeout during synchronization
10 Error I2t power amplier
00 Unknown error
01 I2t power amplier detected
11 External error at digital input detected
00 Unknown external error
01 External error triggering at digital input
12 Error in CAN option
00 Unknown CAN option error
01 CAN option: BusOff error
02 CAN option: Guarding error
Table 6.3 Error list
6.2 Error list
Error messages (error number, error location, error text) for the supply unit are listed in
the following table. In there is an error, the display on the supply unit changes cyclically
between the indications "Er", ">Error number<", ">Error location<". The error messages
can be acknowledged by switching the input ENPO (X4/10).
Error
number
Error
location
Error text
01 Runtime error
00 Unknown runtime error
02 Error in parameter list
00 Unknown runtime error
01 Parameter initialisation failed
02 Parameter virgin initialisation failed
03 Error in parameter saving routine
04 Error in paralist while adding a new parameter
05 Parameter check failed
06 Parameter ID is multiply dened
07 PowerStage data are corrupt
08 Device cannot be used in this voltage level
03 Under voltage
00 Unknown error
01 Undervoltage detected
04
00 Unknown error
01 Overvoltage detected
05 Over current
00 Unknown error
01 Overcurrent (hardware) detected
02 Overcurrent (software) detected
03 Overcurrent (software) detected
Diagnostics

Table of Contents

Other manuals for Keba ServoOne Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keba ServoOne Series and is the answer not in the manual?

Keba ServoOne Series Specifications

General IconGeneral
BrandKeba
ModelServoOne Series
CategoryPower Supply
LanguageEnglish

Related product manuals