Operation Manual ServoOne Supply Unit
69
ID no.: 1101.21B.6-00 Date:04/2020
NOTE:
y During the ashing phase after step7 the save procedure can still be
aborted by pressing any button, without applying the value set. Otherwise
the new value will be saved after ve seconds.
y The modied IP address is only effective after restarting the control
electronics (24-V reset).
5.4.5 Field bus address menu (Fb)
The functions available on this menu item depend on the device's communication
option. For detailed information refer to the relevant specication.
Menu level Pa-
rame-
ter
Value
range
Meaning Explanation
1 2
Fb Ad -
00..xx
or
- -
Field bus
address
Setting for eld bus address (only if eld bus
option used), otherwise indication "- -"
(The maximum value that can be programmed
depends on the option)
Po -
0..3
or
- -
Transmit
power
Setting for bre-optic power output
(only with SERCOS II option), otherwise display
"- -"
Table 5.10 Field bus address menu
Example conguration of the subnet mask
In this example the subnet mask is changed from 255.255.255.0 to 122.255.255.0.
T1
T2
Tx
Tx
back
back
back
several actuations
of buttonTx (X = 1, 2)
until the desired menu
appears in the display
single actuation
of button Tx (X = 1, 2)
simultaneous actuation
of both buttons T1 and T2
Actuation of
any button
accept
>5 s>5 s
<5 s
T2
<5 s
T1 T2
T1 T2
T1 T2
back
T1 T2
back
T1 T2
T1 T2
T1 T2
T1 T2
Value NOT
saved
Value
saved
T1
T2
T1
T1
back
T1 T2
T2
Figure 5.8 Example conguration of the subnet mask
Commissioning