Operation Manual ServoOne Supply Unit
29
ID no.: 1101.21B.6-00 Date:04/2020
4 Electrical installation
4.1 Before you start
It is imperative you pay attention to the following warnings and safety instructions prior to
and during installation.
DANGER! Risk of injury due to electrical power!
• Carelessnesswillresultinseriousinjuriesordeath.
Nevermakeordisconnectelectricalconnectionswhiletheyareelectricallylive!Beforemaking
anychange
thedeviceistobedisconnectedfromthemains.Even30minutesafterswitchingoffthe
mainssupplydangerouslyhighvoltagesof≥50Vmaystillbepresent(capacitorcharge).The
dischargingtimedependsonthecontrollersconnectedtothemulti-axissystem.Socheckthat
electricalpowerisnotpresent!
OnlyoncetheDClinkvoltagehasdroppedtolessthan50VDC(tobemeasuredonsizeBG5
andBG6atterminalsX11/L+andX11/L-andonsizeBG7atterminalsX11/ZK+andX11/ZK-)
areyouallowedtoworkonthedevice.
AnyexistingadditionalDClinkconnectionsaswellastheconnectionsforallcomponentsin
themainsinputareaaretobecheckedinrelationtoeachotherandinrelationtoearthto
ensuretheyarenotcarryinganyelectricalpower.Ifnecessary,allcableconnectionsaretobe
dischargedusingsuitablemeans.
Warning! Risk of injury due to electrical power!
• Carelessnessmayresultinseriousinjuriesordeath.
Adangerousvoltagemaybepresentatthedevice,evenifthedevicedoesnotemitanyvisual
oraudiblesignals/indications,e.g.forBG5andBG6a:withmainsvoltageonterminalX12or
X21switchedonandnocontrolsupply+24VonX9,X10;orforBG7:withmainsvoltageon
terminalX12orX45andnocontrolsupply+24VonX44.Socheckthatelectricalpoweris
notpresent!
WARNING! Risk of injury due to hot surfaces on the device!
• Carelessness may result in serious burns.
Thedeviceandespeciallytheheatsinkheatupsignicantlyduringoperationandcanreach
temperaturesofupto100°C.Thechokesconnectedalsoheatupduringoperationandcan
reachtemperaturesofupto145°C.Priortostartingwork,makesurethedevicehascooled
down.
Ontouchingthereisariskofburnstotheskin.Forthisreasonprovideprotectionagainst
touching.
Duringmountingmaintainanappropriatedistancetoneighbouringassemblies.
NOTE:
On installing the ServoOne multi-axis system, it is imperative the operation
manual for the DC axis controllers is also followed.
Electrical installation

Table of Contents

Other manuals for Keba ServoOne Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keba ServoOne Series and is the answer not in the manual?

Keba ServoOne Series Specifications

General IconGeneral
BrandKeba
ModelServoOne Series
CategoryPower Supply
LanguageEnglish

Related product manuals