1.5.2 Voltage-current regulator inspection
When main wiring terminal is normal, check if plug of voltage-current regulator is of poor contact and measure
impedance value between terminals of voltage-current regulator itself.
* Attention
• Do not touch the metal part of multimeter probe
with your finger.
• Check with a multimeter. If impedance values
measured by different multimeters are not the same,
it perhaps the inspection is not correct.
When impedance value between terminals is
abnormal, replace voltage regulator.
1.6 Magneto Charging Coil
* Attention
Inspection of magneto charging coil can be performed on the engine.
Inspection
Disconnect the 6P connector on the magneto.
Use a multimeter to measure impedance value between white coil of magneto and vehicle block.
Standard value: 0.5-10Ω (20℃)
If measured value exceeds the standard, the magneto coiling shall be replaced.