27
EN
Press”+” to display “9 Press “P”, the display shows
0” to indicate that the step/step
command has the Open/Stop/
Close function (default setting)
Press”+”, “1” appears to indi-
cate that the step/step com-
mand can only open
4.16 Opening command setting
It is possible to change the functioning of the open/stop/close command to only open
By enabling this function, the
Step/Step command permits
opening by accepting only re-
opening during closing.
With the function “7=1” auto-
matic closure enabled at each
command the automatic closing
time is updated
With the function “7=0” automat-
ic closure disabled with the door
open it is possible to reclose it
using the step/step command
4.17 Override and disabling of photocell detection
A
After parameter “9” press
“+” to display “A
Press “P”; the display shows
0” to indicate that the function
is disabled, and therefore
photocell detection is active
throughout the stroke (factory
setting)
Press “+” to select the detection
exclusion height of the required
photocell (see table below)
1) It is possible to override closure of the sectional door, even when the photocell contact is open.
- With the door open, press the transmitter button or DOOR command; the automation then signals failure of the closed photocell contact
by emitting three consecutive beeps.
- Release the transmitter button or DOOR command, and within 4 seconds press and hold the same command;
the automation will then override closure for as log as the command (HOLD-TO-RUN) is pressed.
2) It is possible to select a point of photocell detection exclusion from the ground, by means of function “A” (last item after function “9”)
Note: in order to exit the programming and save the parameters push P button for 5 seconds.
Value Description
0 Photocell detection enabled
1 Photocell detection disabled at 10 cm from point of closure
2 Photocell detection disabled at 20 cm from point of closure
3 Photocell detection disabled at 30 cm from point of closure
4 Photocell detection disabled at 40 cm from point of closure
5 Photocell detection disabled at 50 cm from point of closure
6 Photocell detection disabled at 60 cm from point of closure
7 Photocell detection disabled at 70 cm from point of closure
8 Photocell detection disabled at 80 cm from point of closure
9 Photocell detection disabled at 90 cm from point of closure
Note: in order to exit the programming and save the parameters push P button for 5 seconds.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Key Automation VIPER LED VIP10 and is the answer not in the manual?

Key Automation VIPER LED VIP10 Specifications

General IconGeneral
BrandKey Automation
ModelVIPER LED VIP10
CategoryGarage Door Opener
LanguageEnglish

Related product manuals