6 Application Programs
260 Keysight 34970A/34972A User’s Guide
Excel 7.0 Example: ScanChannels Macro
Continued on next page
’"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""
’ This Excel Macro (Visual Basic) configures the 34970A for scanning with the 34901A,
’ 34902A, or 34908A multiplexer modules. When this subroutine is executed, it will
’ scan 5 channels and display the readings on a spreadsheet. You can easily modify the
’ channels in the scan list, number of scans, channel delay, and scan delay. To make these
’ changes, modify the code in the section titled ’SET UP’. Note that you must have one of
’ the above modules installed in slot 100 for this program to run properly. You must also
’ have an GPIB interface card installed in your PC with the VISA or VTL library.
’"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""
Option Explicit
Sub ScanChannels()
Dim columnIndex As Integer ’ The column number of the data
’ "1" indicates the first data column
Dim numberScans As Integer ’ Total number of scans
Dim numberChannels As Integer ’ Total number of scanned channels
Dim ScanInterval As Single ’ Time interval in seconds between scans
Dim points As Integer ’ Reading count in instrument memory
Dim replyString As String ’ Store the string returned from instrument
Dim scanList As String ’ List of channels included in scan
Dim channelDelay As Single ’ Delay between relay closure and measurement
Dim Channel As Integer
Range("a1:ba40").ClearContents ’ Clear the spreadsheet
’"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""
’ To change the GPIB address, modify the variable ’VISAaddr’ below.
VISAaddr = "9"
OpenPort ’ Open communications on GPIB
SendSCPI "*RST" ’ Issue a Factory Reset to the instrument
’"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""
SET UP: Modify this section to select the scan interval, the scan count,
’ and channel delay.
’ These are variables that are used to set the scan parameters
ScanInterval = 10 ’ Delay (in secs) between scans
numberScans = 3 ’ Number of scan sweeps to measure
channelDelay = 0.1 ’ Delay (in secs) between relay closure and measurement
’ To delete channels from the scan list, modify the scan list string variable
’ ’scanList’ below. To add channels to the scan list, modify ’scanList’ and then
’ configure the channel using the CONFigure command.
’ ’scanList’ is the list of channels in the scan list; note that this does not have
’ to include all configured channels in the instrument.
scanList = "(@101,102,110:112)"
SendSCPI "CONF:TEMP TC,T,(@101)" ’ Configure channel 101 for temperature
SendSCPI "CONF:TEMP TC,K,(@102)" ’ Configure channel 102 for temperature
SendSCPI "CONF:TEMP THER,5000,(@103)" ’ Configure channel 103 for temperature
SendSCPI "CONF:VOLT:DC (@110,111,112)" ’ Configure three channels for DC volts
’"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight 34972A and is the answer not in the manual?

Keysight 34972A Specifications

General IconGeneral
Model34972A
CategoryData Acquisition/Switch Unit
ManufacturerKeysight Technologies
Scan RateUp to 250 channels/sec
Voltage Measurement Range100 mV to 300 V
Resistance Measurement Range100 Ω to 100 MΩ
Operating Temperature0 °C to 55 °C
Storage Temperature-40 °C to 70 °C
Switching ModulesSupports plug-in modules
Current Measurement Range1 µA to 1 A
Temperature MeasurementThermocouples, RTDs, and Thermistors
InterfaceUSB, LAN
Memory50, 000 readings
Weight3.6 kg