EasyManua.ls Logo

KTM 2008 690 SMC EU - 39;IGNITION SYSTEM; Alternator - Checking the Stator Winding

KTM 2008 690 SMC EU
227 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39/IGNITION SYSTEM 158
23.1Alternator - checking the stator winding
Condition
The stator is disconnected.
Reinstall the fuel tank.
600894-10
Stator winding, measurement I - check the resistance
Measure the resistance between the specified points.
Stator, connector EN pin 1 Stator, connector EN pin 2
Alternator
Resistance of stator winding at:
20 °C (68 °F)
1
» If the displayed value is not equal to the setpoint value:
Replace the stator.
Stator winding, measurement II - check the resistance
Measure the resistance between the specified points.
Stator, connector EN pin 1 Stator, connector EN pin 3
Alternator
Resistance of stator winding at:
20 °C (68 °F)
1
» If the displayed value is not equal to the setpoint value:
Replace the stator.
600894-10 601014-10
Stator winding - check for a short circuit to ground (terminal 31)
Measure the resistance between the specified points.
Stator, connector EN pin 1 Measuring point Ground ()
Resistance
» If the displayed value is not equal to the setpoint value:
Replace the stator.
23.2Checking the spark plug connector
Condition
Spark plug connector cylinder 1 has been removed.
600893-10
Measure the resistance between the specified points.
Measuring point 1 Measuring point 2
Spark plug connector
Resistance at: 20 °C (68 °F) 4.3… 5.7 k
» If the specification is not reached:
Change the spark plug connector.