04/SHOCK ABSORBER, SWINGARM 44
200269-10
– When the pressure gauge reaches the specified value, turn the Damper control
lever to Vacuum.
Guideline
3 bar
The pressure gauge falls to the specified value.
0 bar
200270-10
– When the pressure gauge reaches the specified value, turn the Oil reservoir con-
trol lever to Vacuum.
Guideline
0 bar
The vacuum gauge falls to the specified value.
8 mbar
200267-10
– When the vacuum gauge reaches the specified value, turn the Oil reservoir con-
trol lever to Equalize Pressure.
Guideline
8 mbar
The pressure gauge falls to the specified value.
0 bar
200268-10
– When the pressure gauge reaches the specified value, turn the Damper control
lever to Pressure.
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge rises to the specified value.
3 bar
200269-10
– When the pressure gauge reaches the specified value, turn the Damper control
lever to Vacuum.
Guideline
3 bar
The pressure gauge falls to the specified value.
0 bar
– When the pressure gauge reaches the specified value, operate the On/Off switch.
Guideline
0 bar
The vacuum pump is switched off.
– Remove the adapter.
Info
Hold the damper so that the filling port is at the highest point.
– Remove the filling port.
A little oil is forced out of the damper.