KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021 Page - 233 -
After confirmation with ENTER the saved
message appears.
3.3 Enter the nominal speed
The SIL-3 shaft copying system can detect overspeed at 115% of nominal speed.
For this, the nominal speed must be entered.
The default value is 5,00 m/s. This value
must be adjusted on the nominal speed of
the elevator system.
The entry is completed with the ENTER-Key.
When the value ist accepted, the saved mes-
sage appears.
3.4 Teaching the limit swich UP
3.4a Normal pit-brow
3.4b Reduced pit-brow
Key down:
Key down:
Set to YES with yellow keys.