KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021 Page - 63 -
Car Light Delay
10 to 6500 sec
60 sec
Car Indicator Automatic Off
No,Yes
No
Car Indicator Delay
10 to 6500 sec
120 sec
Floor Indicator Automatic Off
No,Yes
No
Floor Indicator Delay
10 to 6500 sec
180 sec
FU Standby Automatic Off
No,Yes
No
FU Standby Delay
10 to 6500 sec
60 sec
FU Switch Off Automatic Off
No,Yes
No
FU Switch Off Delay
10 to 6500 sec
60 sec
Door Drive Automatic Off
No,Yes
No
Delay
10 to 6500 sec
60 sec
Mode S1 D613 Standby
No,Yes
No
Mode S2 D613 Standby
No,Yes
No
B609 Emergency Power service
Emergency Power Service
No/yes, generator, accupower,brake open, EVA90
No
Emergency Power Service floor 1
Next floor, 1 to 64
1
Entrance Open
1, 2, 1+2
1
Follow-Circuit
No,Yes
No
Piezo Buzzer
Off / on
off
Follow Circuit Deadtime
10 to 600 sec
360 sec
Direction From Inverter
No / Yes
No
Drive Command VE->V0 at ZONE
B610 Emergency Fire Service
Emergency Fire Service
No, Yes-1, Yes-2, Yes-3, dynamic across fire, dynamic stop fire
1. Priority
1 to max.
2
1. P. Entrance open
1, 2, 1+2
1
2. Priority
1 to max.
2
2.P. Entrance open
1, 2, 1+2
1
3. Priority
1 to max.
3
3.P. Entrance open
1, 2, 1+2
1
Piezo Buzzer
Off , on
off
Emergency Fire Service Blocked
Buzzer OFF / ON
ON
Emergency Fire Service Input
Not inverted/ inverted
Not inverted
Emergency Fire Service Swiss Version
No,Yes
No
Door state
Keep open, closed after 1 60s
Always open
Schindler ID
Normal, inverted
Normal
B611 Fire Fighter service
Firefighter Travel
No,Yes, 1 priority, 2 priorities, 3 priorities
No
1. Priority
1 to max.
2
1.P. Entrance open
1, 2, 1+2
1
2. Priority
1 to max.
2
2.P. Entrance open
1, 2, 1+2
1
3. Priority
1 to max.
2
3.P. Entrance open
1, 2, 1+2
1
Firefighter Travel Input
Not inverted/ inverted
Not inverted
Firefighter Travel Model
German / English / Australian / EN 81-72:2003 / EN81-72 Frankfurt
EN 81-72
Buzzer on leveling
Active /deactive
deactive
Buzzer at request
On/Off
Floor- / Inside call blocking deactiva-
tion if FW-Operation
No /Yes
Yes
B612 Rescue Travel
Rescue Travel
No, Yes E30
No
Collection Floor
1 to max.
3
Collection Floor Wait Time
10 to 2000 sec.
600 sec.
Rescue Floor
1 to max.
2
Rescue Floor Wait Time
1 to 2000 sec.
120 sec.
Rescue Travel Repeat travel
1 to 10x
20 x
B613 Guide Mode
Guide Mode
No, Active by E23
No
Door Control
Automatic / Manuel
Automatic
Floor Calls reset after :
Never reset, 1 to 60 Min
60 Min
Call Request :
Blink Car/ Blink Floor
Blink Carcalls
B614 Hotel Stopping
Main Floor
No/Up/Down/Up+Down
No
B615 Time relay