EasyManua.ls Logo

KYMCO MX 125 - Page 29

KYMCO MX 125
181 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. GENERAL INFORMATION
1-27
MX’er SYSTEM
POOR CHARGING (BATTERY OVER DISCHARGING OR OVERCHARGING)
Undercharging
Inspection/Adjustment Symptom
Probable Cause
Dead battery
Faulty battery
Faulty A.C. generator coil
Broken yellow wire
Shorted pink and yellow
wires
Broken red wire
Faulty regulator/rectifier
Poorly connected coupler
Faulty A.C. generator
Overcharging
Broken green wire
Poorly connected coupler
Faulty regulator/rectifier
Start engine and test
limit voltage of battery
terminals
Connect battery (+) wire
to regulator/rectifier
coupler red wire and
battery (-) wire to engine
g
round and test volta
g
e
Inspection/Adjustment Symptom
Normal voltage
B
attery
h
as vo
l
tage
with ignition
switch “ON”
Normal
Voltage does no
t
increase
Normal
Abnormal
B
attery
h
as no
voltage with ignition
switc
h
“ON”
Resistance too high
Normal voltage No voltage
Normal
Abnormal
Measure resistance
between AC generator
coil terminals
Probable Cause
Check regulator/rectifier
coupler for loose
connection
Connect battery (+) wire
to regulator/rectifier
coupler green wire and
battery (-) wire to engine
g
round and test volta
g
e
Check regulator/rectifier
coupler for loose
connection

Table of Contents

Related product manuals