2B-28 Developed for Training Purposes Leerjet 35/36
February 2004
CAE SimuFlite
Starting Engines
The Starting Engines checklist is completed prior to engine
start. Both engines should be started prior to taxi.
Passengers/Baggage . . . . . . . . . . . . . . BRIEFED/SECURED
Cabin Door . . . . . . . . . . . . . . . . TWO HANDLES FORWARD/
LIGHT OUT
The DOOR annunciator does not extinguish until all door
latch pins are in place and the door actuator motor is oper-
ated to back the closer hooks off the upper door catches.
The upper door is an emergency exit.
L/R Fuel Cmptr Switches . . . . . . . . . . . . . . . . . . . . . . . . . ON
L/R Fuel Cmptr Lights . . . . . . . . . . . . . . . . . . . . CHECK/OUT
Batteries . . . . . . . . . . . . . . . . . . .CHECK FOR MIN VOLTAGE
Lead-acid batteries show at least 24V DC; ni-cad batteries
show at least 23V DC.
Inverters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PRI ON
Air Conditioning/Aux Heat . . . . . . . . . . . . . . . . FAN OR OFF
Do not use the Freon system or auxiliary heat during start.
This step reduces voltage draw and amperage spike cre-
ated when the starter switch is placed in the generator posi-
tion.
Rotating Beacon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ON
External Lighting . . . . . . . . . . . . . . . . . . . . . . AS REQUIRED
Thrust Levers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CUTOFF
Parking Brake. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SET
Hydraulic Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF