2B-30 Developed for Training Purposes Leerjet 35/36
December 1998
CAE SimuFlite
Q
If engine does not start, observe the starter cooling
requirements below:
This cycle may be repeated
If batteries used for start:
START-GEN Switch . . . . . . . . . . . . . . . . . . . . . GEN AT IDLE
On S/Ns 35-002 through 147; 36-002 through 035:
Prior to START-GEN Switch to GEN
BAT 1 or 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
Prior to starting second engine or if taxiing with single
engine operating and ammeter reads less than 175A, both
battery switches to ON.
(If only one engine is started at this time, return to page
2B-9 and continue with Warning Systems Check.)
If GPU used for start:
START-GEN Switch . . . . . . . . . . . . . . . . . . . . . OFF AT IDLE
The AFM does not make a distinction between battery and
GPU starts. It is widely accepted, however, to leave the gen-
erators off after starting until the GPU has been discon-
nected.
START ATTEMPT WAIT
1 1 Minute
2 1 Minute
3 15 Minutes
4 1 Minute
5 1 Minute
6 1 Hour