2B-32 Developed for Training Purposes Leerjet 35/36
December 1998
CAE SimuFlite
Generators/DC Volts and Amps . . . . . . . . . . . ON/CHECKED
Check generator output, DC volts, and amps.
Current Limiters. . . . . . . . . . . . . . . . . . . . . . . . . . . CHECKED
CUR LIM Annunciator. . . . . . . . . . . . . . . . . EXTINGUISHED
If CUR LIM annunciator not installed:
Rotary Test Switch . . . . . . . . . . . . . . . CURRENT LIMITER L
Test Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEPRESS
The green indicator annunciator illuminates if the left current
limiter is functional.
Rotary Test Switch . . . . . . . . . . . . . . . CURRENT LIMITER R
The green indicator annunciator illuminates if the right cur-
rent limiter is functional. Repeat the Current Limiter test after
both engines have been started.
On early model aircraft not equipped with CUR LIM annun-
ciator or rotary test switch CURRENT position:
Main Bus Tie CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PULL
Left Generator Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
Check ammeter indications; right amp indication should
double.
Left Generator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ON
Right Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
Left ammeter indication should double.
Right Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ON
Main Bus Tie CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . RESET
If ammeter indications do not change during test, a current
limiter has failed. Do not fly the aircraft until corrected.