Leerjet 35/36 Developed for Training Purposes 2B-75
December 1998
Expanded Normal Procedures
Restoring from Indefinite Storage
(More than 6 Months)
In addition to procedures required for restoring from Prolonged
Storage, the following are performed:
Engine Fire Extinguisher System. . . . . . . . . . . . . CHECKED
Hydrostatically test and service engine fire extinguisher con-
tainers and install engine fire extinguisher containers and
cartridges (See Maintenance Manual for details).
400-Hour Inspection . . . . . . . . . . . . . . . . . . . . PERFORMED
Perform 400-hour inspection as described in Maintenance
Manual.