Step2.Unlockandremovetheleft-sidecover(see“Removingtheleft-sidecover”onpage184).
Step3.Removetheadapter(see“Removinganadapter”onpage213).
Step4.GraspthememorymoduleandlifttoremoveitfromtheconnectorontheServeRAIDadapter.
Figure137.Memorycardremoval
Ifyouareinstructedtoreturntheservercomponentoroptionaldevice,followallpackaginginstructions,
anduseanypackagingmaterialsforshippingthataresuppliedtoyou.
InstallinganoptionalServeRAIDadaptermemorymodule
UsethisinformationtoinstallanoptionalServeRAIDadaptermemorymodule.
Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage35.
Ifyouarereplacingaservercomponentintheserver,youneedtoturnofftheserverandperipheraldevices,
anddisconnectthepowercordsandallexternalcables.
ToinstallanoptionalServeRAIDadaptermemorymodule,completethefollowingsteps.
Step1.Carefullyturntheserveronitssidesothatitislyingflat,withthecoverfacingup.
Attention:Donotallowtheservertofallover.
Step2.Unlockandremovetheleft-sidecover(see“Removingtheleft-sidecover”onpage184).
Step3.RemovetheServeRAIDadapterifnecessary(see“Removinganadapter”onpage213).
Step4.Touchthestatic-protectivepackagethatcontainsthememorycardtoanyunpaintedmetalsurface
ontheserver;then,removethememorycardfromthepackage.
Step5.AlignthememorymodulewiththeconnectorontheServeRAIDadapterandpushitintothe
connectoruntilitisfirmlyseated.
224Systemx3500M4InstallationandServiceGuide