TheserverhassixPCIinterfaceslots.Slot1cansupportPCIExpressorPCI-Xadaptersthroughan
optionalPCI-Xinterposercard.See“Installinganadapter”onpage216
fordetailedinformation.
•Redundantconnection
TheadditionoftheoptionalEthernetdaughtercardprovidesfailovercapabilitytoaredundantEthernet
connectionwiththeapplicableapplicationinstalled.IfaproblemoccurswiththeprimaryEthernet
connectionandtheoptionalEthernetdaughtercardisinstalledontheserver,allEthernettrafficthatis
associatedwiththeprimaryconnectionisautomaticallyswitchedtotheoptionalredundantEthernet
daughtercardconnection.Iftheapplicabledevicedriversareinstalled,thisswitchingoccurswithout
datalossandwithoutuserintervention.
•Redundantcoolingandoptionalpowercapabilities
Theserversupportsamaximumoftwo750-wattor900-watthot-swappowersuppliesandsix
simple-swapfans,whichprovideredundancyandhot-swapcapabilityforatypicalconfiguration.The
redundantcoolingbythefansintheserverenablescontinuedoperationifoneofthefansfails.Theserver
comeswithone750-wattor900-watthot-swappowersupplyandtwofans.
Youmustinstallfan2whenyouinstallthesecondmicroprocessorintheserver.Youcanorderthe
optionalfan4,5,and6forcoolingredundancy.Youcanorderthesecondoptionalpowersupply
forpowerredundancy.
Notes:
1.Youcannotmix750-wattand900-wattpowersuppliesintheserver.
2.Theserverisnotrunninginpowerredundantmodewithtwo225WGPUsinstalled,two900-watt
powersuppliesarerequired.
•Remotepresenceandblue-screencapturefeatures
Theremotepresenceandblue-screencapturefeaturesareintegratedfunctionsoftheIntegrated
ManagementModuleII(IMM2).Theremotepresencefeatureprovidesthefollowingfunctions:
–Remotelyviewingvideowithgraphicsresolutionsupto1600x1200at75Hz,regardlessofthesystem
state
–Remotelyaccessingtheserver,usingthekeyboardandmousefromaremoteclient
–MappingtheCDorDVDdrive,diskettedrive,andUSBflashdriveonaremoteclient,andmappingISO
anddisketteimagefilesasvirtualdrivesthatareavailableforusebytheserver
–UploadingadisketteimagetotheIMM2memoryandmappingittotheserverasavirtualdrive
Theblue-screencapturefeaturecapturesthevideodisplaycontentsbeforetheIMM2restartstheserver
whentheIMM2detectsanoperating-systemhangcondition.Asystemadministratorcanusethe
blue-screencapturefeaturetoassistindeterminingthecauseofthehangcondition.
See“Usingtheremotepresenceandblue-screencapturefeatures”onpage115foradditionalinformation.
•ServeRAIDsupport
TheServeRAIDadapterprovideshardwareredundantarrayofindependentdisks(RAID)supportto
createconfigurations.ThestandardRAIDadapterprovidesRAIDlevels0,1,and10.AnoptionalRAID
adapterisavailableforpurchase.
•Systems-managementcapabilities
TheservercomeswithanIntegratedManagementModuleII(IMM2).WhentheIMM2isusedwiththe
systems-managementsoftwarethatcomeswiththeserver,youcanmanagethefunctionsoftheserver
locallyandremotely.TheIMM2alsoprovidessystemmonitoring,eventrecording,andnetworkalert
capability.Thesystems-managementconnectorontherearoftheserverisdedicatedtotheIMM2.The
dedicatedsystems-managementconnectorprovidesadditionalsecuritybyphysicallyseparatingthe
managementnetworktrafficfromtheproductionnetwork.YoucanusetheSetuputilitytoconfigurethe
servertouseadedicatedsystems-managementnetworkorasharednetwork.
•UEFI-compliantserverfirmware
14Systemx3500M4InstallationandServiceGuide