a.  Note the orientation of the flash power module; then, gently insert the flash power module 
into the retaining clip at one side as shown.
b. 
Press the flash power module down on the other side until it snaps into place.
Step 2.  Route the flash power module cable and connect it to the RAID adapter. 
Figure 67. Flash power module cable routing
After you finish
1.  Reinstall the server cover. See “Install the server cover” on page 190.
2.  Complete the parts replacement. See “Complete the parts replacement” on page 206.
Foot stands replacement
Use this information to remove and install the foot stands.
Note: This section applies only to server models that have foot stands installed.
Remove the foot stands
Use this information to remove the foot stands.
About this task
S033 
CAUTION: 
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with 
metal, which might result in spattered metal, burns, or both. 
Attention: 
•  Read “Installation guidelines” on page 57 to ensure that you work safely.
102
ThinkSystem ST650 V2 Maintenance Manual