Figure 83. Installing a Torx T30 nut into the heat sink
Note: Do not touch the gold contacts on the bottom of the processor.
a.
Rotate the anti-tilt wire bail inwards.
b.
Orient the Torx T30 nut under the anti-tilt wire bail; then, align the Torx T30 nut with the
socket at an angle as shown.
c.
Push the lower edge of the Torx T30 nut into the socket until it clicks into place. Make sure
the Torx T30 nut is secured under the four clips in the socket.
After you finish
1. Reinstall the PHM. See “Install a processor and heat sink” on page 183.
2. Reinstall the air baffle. See “Install the air baffle” on page 74.
3. Reinstall all the flash power modules. See “Install a flash power module” on page 100.
4. Reinstall the server cover. See “Install the server cover” on page 190.
5. Reinstall the hot-swap redundant power supply. See “Install the hot-swap power supply” on page 173.
6. Complete the parts replacement. See “Complete the parts replacement” on page 206.
Internal CFF adapter replacement
Use this information to remove and install the internal CFF RAID adapter, internal CFF HBA adapter, or
internal CFF RAID expander adapter.
Remove the internal CFF adapter
Use this information to remove the internal CFF RAID adapter, internal CFF HBA adapter, or internal CFF
RAID expander adapter.
About this task
S002
122
ThinkSystem ST650 V2 Maintenance Manual