Step21.Restarttheserver.Thesystembeginsthepower-onself-test(POST).
Step22.Iftheserecoveryeffortsfail,contactyourLenovoservicerepresentativeforsupport.
In-bandautomatedbootrecoverymethod
Usethisinformationtorecovertheserverfirmwareandrestoretheserveroperationtotheprimarybank.
Note:UsethismethodiftheBOARDLEDislitandthereisalogentryorBootingBackupImageisdisplayed
onthefirmwaresplashscreen;otherwise,usethein-bandmanualrecoverymethod.
Step1.Boottheservertoanoperatingsystemthatissupportedbythefirmwareupdatepackagethat
youdownloaded.
Step2.Performthefirmwareupdatebyfollowingtheinstructionsthatareinthefirmwareupdatepackage
readmefile.
Step3.Restarttheserver.
Step4.Atthefirmwaresplashscreen,pressF3whenpromptedtorestoretotheprimarybank.The
serverbootsfromtheprimarybank.
Out-of-bandmethod
Usethisinformationtorecovertheserverfirmwareandrestoretheserveroperationtotheprimarybank.
SeetheIMM2.1documentation(IntegratedManagementModuleIIUser'sGuide)at
www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5089484&brandind=5000008.
Automatedbootrecovery(ABR)
Whiletheserverisstarting,iftheintegratedmanagementmoduleIIdetectsproblemswiththeserver
firmwareintheprimarybank,theserverautomaticallyswitchestothebackupfirmwarebankandgivesyou
theopportunitytorecoverthefirmwareintheprimarybank.
ForinstructionsforrecoveringtheUEFIfirmware,see“Recoveringtheserverfirmware(UEFIupdatefailure)”
onpage92.Afteryouhaverecoveredthefirmwareintheprimarybank,completethefollowingsteps:
Step1.Restarttheserver.
Step2.WhenthepromptPressF3torestoretoprimaryisdisplayed,pressF3tostarttheserverfrom
theprimarybank.
Nx-bootfailure
Configurationchanges,suchasaddeddevicesoradapterfirmwareupdates,andfirmwareorapplication
codeproblemscancausetheservertofailPOST(thepower-onself-test).
Ifthisoccurs,theserverrespondsineitherofthefollowingways:
TheserverrestartsautomaticallyandattemptsPOSTagain.
Theserverstopsresponding,andyoumustmanuallyrestarttheserverfortheservertoattemptPOST
again.
Afteraspecifiednumberofconsecutiveattempts(automaticormanual),theNx-bootfailurefeaturecauses
theservertoreverttothedefaultUEFIconfigurationandstarttheSetuputilitysothatyoucanmakethe
necessarycorrectionstotheconfigurationandrestarttheserver.Iftheserverisunabletosuccessfully
completePOSTwiththedefaultconfiguration,theremightbeaproblemwiththesystemboard.
94LenovoSystemx3550M5InstallationandServiceGuide