Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.ChecktheEthernetcablefordamageandensurecorrectcabletypeandattachment.
2.Checkcomponentfirmwarelevelandupgradeifnecessary.Theinstalledfirmwarelevelcanbe
foundintheDSADiagnosticEventLogwithintheFirmware/VPDsectionforthiscomponent.
3.Rerunthetest.
4.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
DSALSIharddrivetestresults
ThefollowingmessagescanresultwhenyouruntheLSIharddrivetest.
TestresultsfortheDSALSIharddrivetest
ThefollowingmessagescanresultwhenyouruntheDSALSIharddrivetest.
407-000-000:LSIESG:DiskDefaultDiagnosticTestPassed
Thetestpassed.
Recoverable
No
Severity
Event
Serviceable
No
Automaticallynotifysupport
No
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
407-800-000:LSIESG:DiskDefaultDiagnosticTestAborted
904LenovoSystemx3550M5InstallationandServiceGuide