Lenovo x3550 M5 - IMM Events that Automatically Notify Support

Lenovo x3550 M5
1060 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AutomaticallycontactService
IfthisfieldissettoYes,andyouhaveenabledElectronicServiceAgent(ESA),LenovoSupportwillbe
notifiedautomaticallyiftheeventisgenerated.
WhileyouwaitforLenovoSupporttocall,youcanperformtherecommendedactionsfortheevent.
Userresponse
Theactionsthatyoushouldperformtosolvetheevent.
Performthestepslistedinthissectionintheordershownuntiltheproblemissolved.Afteryouperform
alloftheactionsthataredescribedinthisfield,ifyoucannotsolvetheproblem,contactLenovoSupport.
Note:Thislistincludeserrorcodesandmessagesthatmightnotapplytothismachinetypeandmodel.
ThefollowingisthelistofIMM2.1errormessagesandsuggestedactionstocorrectthedetectedserver
problems.FormoreinformationaboutIMM2.1,seetheIntegratedManagementModuleIIUser'sGuideat
www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5089484&brandind=5000008.
IMMEventsthatautomaticallynotifySupport
YoucanconfiguretheIntegratedManagementModuleII(IMM2)toautomaticallynotifySupport(alsoknown
ascallhome)ifcertaintypesoferrorsareencountered.Ifyouhaveconfiguredthisfunction,seethetablefor
alistofeventsthatautomaticallynotifySupport.
Table47.EventsthatautomaticallynotifySupport
EventIDMessageString
Automatically
NotifySupport
40000086-00000000
TestCallHomeGeneratedbyuser[arg1].
Yes
40000087-00000000
ManualCallHomebyuser[arg1]:[arg2].
Yes
80010202-0701ffff
Numericsensor[NumericSensorElementName]goinglow
(lowercritical)hasasserted.
Yes
80010902-0701ffff
Numericsensor[NumericSensorElementName]going
high(uppercritical)hasasserted.
Yes
806f0021-2201ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(NoOpROM
Space)
Yes
806f0021-2582ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(AllPCIError)
Yes
806f0021-2c01ffff
Faultinslot[PhysicalConnectorSystemElementName]
onsystem[ComputerSystemElementName].(ML2Card
Fault)
Yes
806f0021-3001ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(InternalRAID)
Yes
806f0021-3002ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(PCI2)
Yes
806f0021-3003ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(PCI3)
Yes
806f0108-0a01ffff
[PowerSupplyElementName]hasFailed.(PowerSupply1)
Yes
806f0108-0a02ffff
[PowerSupplyElementName]hasFailed.(PowerSupply2)
Yes
278LenovoSystemx3550M5InstallationandServiceGuide