EasyManua.ls Logo

Lenovo x3550 M5 - Replacing the Serveraid Adapter Memory Module

Lenovo x3550 M5
1060 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”on
page116
.
Step2.Turnofftheserverandperipheraldevicesanddisconnectallpowercords.
Step3.Removethecover(see“Removingthecover”onpage119).
Step4.RemovetheServeRAIDSAS/SATAcontroller(see“RemovingaServeRAIDSAS/SATAcontroller”
onpage184).
Step5.Presstheretentiontabsawayfromthememorymodule;then,graspthememorymoduleandliftto
removeitfromtheconnectorontheServeRAIDadapter.
ServeRAID adapter
ServeRAID
memory module
Retention
bracket
Figure112.ServeRAIDmemorymoduleremoval
Ifyouareinstructedtoreturnthememorymodule,followallpackaginginstructions,anduseanypackaging
materialsforshippingthataresuppliedtoyou.
ReplacingtheServeRAIDadaptermemorymodule
UsethisinformationtoreplacetheServeRAIDadaptermemorymodule.
ToinstalltheServeRAIDadaptermemorymodule,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”on
page116.
Step2.Turnofftheserverandperipheraldevicesanddisconnectallpowercords.
Step3.Removethecover(see“Removingthecover”onpage119).
Step4.RemovetheServeRAIDSAS/SATAcontroller(see“RemovingaServeRAIDSAS/SATAcontroller”
onpage184).
Step5.AlignthememorymodulewiththeconnectorontheServeRAIDadapterandpushitintothe
connectoruntilitisfirmlyseated.
190LenovoSystemx3550M5InstallationandServiceGuide

Table of Contents

Related product manuals