TheIMM2accountpassword(1of12accounts).ThedefaultvalueisPASSW0RD(with
azero0notanO).
ExamplethatdoesnotusetheuserIDandpassworddefaultvalues:
oneclicongsetSYSTEM_PROD_DATA.SYsInfoUUID<uuid_value>[immimm_user_id:imm_password@imm_internal_ip]
ExamplethatdoesusetheuserIDandpassworddefaultvalues:
oneclicongsetSYSTEM_PROD_DATA.SysInfoUUID<uuid_value>
Bootablemedia:
YoucanalsobuildabootablemediumusingtheapplicationsavailablethroughtheToolsCenter
Websiteathttps://support.lenovo.com/us/en/documents/LNVO-CENTER.Fromthe
ToolsCenterpage,scrolldownfortheavailabletools.
Step5.RestarttheIMM.
Step6.Restarttheserver.
UpdatingtheDMI/SMBIOSdata
TheDesktopManagementInterface(DMI)mustbeupdatedwhenthesystemboardisreplaced.Usethe
AdvancedSettingsUtilitytoupdatetheDMIintheUEFI-basedserver.
TheDesktopManagementInterface(DMI)mustbeupdatedwhenthesystemboardisreplaced.UseLenovo
ToolsCenterSuiteCLItoupdatetheDMIintheUEFI-basedserver.LenovoToolsCenterSuiteCLIisanonline
toolthatsupportsseveraloperatingsystems.Makesurethatyoudownloadtheversionforyouroperating
system.YoucandownloadLenovoToolsCenterSuiteCLIfromtheLenovoWebsite.TodownloadLenovo
ToolsCenterSuiteCLIandupdatetheDMI,dothefollowing:
Note:ChangesaremadeperiodicallytotheLenovoWebsite.Theactualproceduremightvaryslightly
fromwhatisdescribedinthisdocument.
Step1.Gotohttps://support.lenovo.com/us/en/documents/LNVO-TCLI.Then,findanddownloadLenovo
ToolsCenterSuiteCLIversionforyouroperatingsystem.
Step2.LenovoToolsCenterSuiteCLIsetstheDMIintheIntegratedManagementModule2.1(IMM2.1).
SelectoneofthefollowingmethodstoaccesstheIntegratedManagementModule2.1(IMM2.1)
tosettheDMI:
Onlinefromthetargetsystem,suchasLANorkeyboardconsolestyle(KCS)access
Remoteaccesstothetargetsystem(LANbased)
BootablemediumcontainingLenovoToolsCenterSuiteCLI(LANorKCS,dependingupon
thebootablemedia)
Step3.CopyandunpacktheLenovoToolsCenterSuiteCLIpackage,whichalsoincludesotherrequired
files,totheserver.MakesurethatyouunpacktheLenovoToolsCenterSuiteCLIandtherequired
filestothesamedirectory.Inadditiontotheapplicationexecutable(OneCLIorOneCLI64),the
followingfilesarerequired:
ForWindowsbasedoperatingsystems:
ibm_rndis_server_os.inf
device.cat
ForLinuxbasedoperatingsystems:
cdc_interface.sh
Step4.AfteryouinstallLenovoToolsCenterSuiteCLI,typethefollowingcommandstosettheDMI:
oneclicongsetSYSTEM_PROD_DATA.SysInfoProdName<m/t_model>[access_method]
oneclicongsetSYSTEM_PROD_DATA.SysInfoSerialNum<s/n>[access_method]
oneclicongsetSYSTEM_PROD_DATA.SysEncloseAssetTag<asset_tag>[access_method]