EasyManua.ls Logo

Lenovo x3550 M5 - Page 917

Lenovo x3550 M5
1060 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.Rerunthetest.
3.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
406-903-000:IANet:InterruptsT estFailed
AfailurewasdetectedduringtheInterrupttest.
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Checkcomponentfirmwarelevelandupgradeifnecessary.Theinstalledfirmwarelevelcanbe
foundintheDSADiagnosticEventLogwithintheFirmware/VPDsectionforthiscomponent.
2.Rerunthetest.
3.CheckinterruptassignmentsinthePCIHardwaresectionoftheDSADiagnosticLog.Ifthe
ethernetdeviceissharinginterrupts,ifpossiblemodifytheinterruptassignmentsusingF1
Setuptoassignauniqueinterrupttothedevice.
4.Rerunthetest.
5.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
406-904-000:IANet:LoopbackTestFailed
AfailurewasdetectedduringtheLoopbacktest.
Recoverable
No
Severity
Error
Serviceable
AppendixC.DSAdiagnostictestresults903