Retention lever
Figure211.Retentionleverlocation
Battery holder
Figure212.Batteryorpowermoduleholderlocationfor3.5-inchharddiskdriveservermodels
Step5.Reinstallthehot-swapfans(see“Replacingathermalkit(hot-swapfan)”onpage192).
Step6.(Trainedtechnicianonly)Installthemicroprocessorandheatsink(see“Replacingamicroprocessor
andheatsink”onpage260).
Step7.Reinstallthememorymodules(see“Memorymoduleinstallation”onpage160).
Step8.ReinstalltheServeRAIDSAS/SATAcontroller(see“ReplacingaServeRAIDSAS/SATAcontroller
onpage185).
Step9.Reconnectthecablestothesystemboardthatyoudisconnectedbefore.
Step10.ReinstallthePCIriser-cardassembliesandadapters,ifanywereinstalled(see“Replacingan
adapter”onpage178
and“ReplacingaPCIriser-cardassembly”onpage172).
Step11.Reinstalltheairbaffle(see“Replacingtheairbaffle”onpage122).
Step12.Reinstallthecover(see“Replacingthecover”onpage120).
Step13.Pushthepowersuppliesbackintotheserver.
Step14.Slidetheserverintotherack.
Step15.Reconnectthepowercordsandanycablesthatyouremoved.
Step16.Turnontheperipheraldevicesandtheserver.
Step17.StarttheSetuputilityandresettheconfiguration.
274LenovoSystemx3550M5InstallationandServiceGuide