AlertCategory
System-other
SNMPTrapID
22
CIMInformation
Prefix:IMMID:0028
UserResponse
Iftherewasnooperating-systemerror,completethefollowingstepsuntiltheproblemissolved:
1.Reconfigurethewatchdogtimertoahighervalue.
2.MakesurethattheIMMEthernet-over-USBinterfaceisenabled.
3.ReinstalltheRNDISorcdc_etherdevicedriverfortheoperatingsystem.
4.Disablethewatchdog.
Iftherewasanoperating-systemerror,checktheintegrityoftheinstalledoperatingsystem.
4000001d-00000000:Watchdog[arg1]FailedtoCaptureScreen.
Thismessageisfortheusecasewhereanoperatingsystemerrorhasoccurredandthescreencapture
failed.
Mayalsobeshownas4000001d00000000or0x4000001d00000000
Severity
Error
Serviceable
No
Automaticallynotifysupport
No
AlertCategory
System-other
SNMPTrapID
22
CIMInformation
Prefix:IMMID:0029
UserResponse
Completethefollowingstepsuntiltheproblemissolved:
1.Reconfigurethewatchdogtimertoahighervalue.
2.MakesurethattheIMMEthernetoverUSBinterfaceisenabled.
3.ReinstalltheRNDISorcdc_etherdevicedriverfortheoperatingsystem.
4.Disablethewatchdog.Checktheintegrityoftheinstalledoperatingsystem.
5.UpdatetheIMMfirmware.Important:Someclustersolutionsrequirespecificcodelevelsor
coordinatedcodeupdates.Ifthedeviceispartofaclustersolution,verifythatthelatestlevelof
codeissupportedfortheclustersolutionbeforeyouupdatethecode.
298LenovoSystemx3550M5InstallationandServiceGuide