EasyManua.ls Logo

Lenovo x3550 M5 - Page 909

Lenovo x3550 M5
1060 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No
Severity
Warning
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Removepowercables,waitfor45seconds,reconnectandrerunthetest.
2.Makesurethatthescalabilitycableconnectionsareasperspecification.
3.MakesurethatDSAandBIOS/uEFIareatthelatestlevel.
4.Iftheproblemremains,contactyourtechnical-servicerepresentative.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
401-901-001:EXAPortPingT estFailed
EXAPortPingTestFailed.
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Removepowercables,waitfor45seconds,reconnectandrerunthetest.
2.Makesurethatthescalabilitycableconnectionsareasperspecification.
3.Checkscalabilitycablesforlooseconnections.
4.Replacethescalabilitycable(s)forspecifiedport(s).
5.Iftheproblemremains,contactyourtechnical-servicerepresentative.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
AppendixC.DSAdiagnostictestresults895