Electrical installation − EMS version
Devices in a power range of 0.75 ... 4 kW (3/PE AC 400 V)
Terminal assignment of the power connections
7
121
EDS84DPS424 EN 5.0
7.5.2 Terminal assignment of the power connections
Mains connection
X10 − port for mains, signalling bar, and control bar
Pin Connection Description Data
DESINA type Q4/2, pins Version: 8400 protec EMS
Type designation:
E84DEx... (half wave)
E84DLx... (half wave coded)
84DWTX0100
1 L1 Mains phase L1
Max. 6 mm
2
2 L2 Mains phase L2
3 L3 Mains phase L3
4 MS1 Signalling bar 1
PE PE conductor
11 SS1 Control bar 1
(Half wave/half wave coded)
Max. 2.5 mm
2
12 SS2 Control bar 2 (half wave optional)
X10 − port for mains, power wave / DECA and control bar
Pin Connection Description Data
DESINA type Q4/2, pins Version: 8400 protec EMS
Type designation:
E84DPx... (power wave)
E84DDx... (DECA bus)
84DWTX0100
1 L1 Mains phase L1
Max. 6 mm
2
2 L2 Mains phase L2
3 L3 Mains phase L3
4 SS1 Control bar 1
PE PE conductor
11 Data+ PW+ / DECA+
Max. 2.5 mm
2
12 Data− / DECA−