Electrical installation − EMS version
Control terminals
Synchronous serial interface (SSI)
7
132
EDS84DPS424 EN 5.0
7.6.3 Synchronous serial interface (SSI)
X80 − SSI
Pin Signal Description Data
M12 type, 8−pole sockets
84DPSO05_8
1 CLK+ Pos. clock signal
2 CLK− Neg. clock signal
3 Data+ Pos. data line
4 Data− Neg. data line
5 n. c. Not assigned
6 n. c. Not assigned
7 GIO Reference potential
External supply at 24E: Voltage drop < 2.5 V
Total current for X4x, X50/X8x: 1 A
8 24O 24 V supply of the external SSI encoders