Electrical installation − HighLine/StateLine version
Devices in a power range of 0.75 ... 7.5 kW (3/PE AC 400 V)
Terminal assignment of the power connections
6
87
EDS84DPS424 EN 5.0
6.5.2 Terminal assignment of the power connections
Mains connection
X10 − port for mains
Pin Connection Description Data
DESINA type Q4/2, pins
84DWTX0100
1 L1 Mains phase L1
Max. 6 mm
2
2 L2 Mains phase L2
3 L3 Mains phase L3
PE PE conductor
11 24E External 24−V power supply
Max. 2.5 mm
2
12 GND External reference potential
X10 − mains connection − device version E84DxH...
Pin Connection Description Data
1 4
3
2
Type Molex, Brad Mini−Change, pins
E84DWTXXMO 1
1 L1 Mains phase L1
max. 14 AWG
2 L2 Mains phase L2
3 L3 Mains phase L3
4 PE PE conductor