EasyManua.ls Logo

Lenze 8400 protec - 3 Product Description; Device Features

Lenze 8400 protec
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product description
Device features
3
20
EDS84DPS424 EN 5.0
3 Product description
3.1 Device features
Decentralised 8400 protec frequency inverter Version
Features HighLine StateLine EMS
Power range 0.75 ... 7.5 kW 0.75 ... 4 kW 0.75 ... 7.5 kW
Mounting type Wall−mounted device
Brake management Control of a mechanical motor holding brake
24 V supply
Internal (depending on mains voltage)
24 V buffer voltage possible
(for maintaining the control functionality
in the case of mains failure)
Interfaces
Digital inputs, 6 6 14
can be configured as outputs 2 2 2 or 4
Analog inputs
1
1
1
or optionally synchronous serial interface
(SSI)
Optional: RS485 or/and RS422 2 x RS485
2 x RS422
1 x RS485 / RS422
each
Remote control, infrared (IrRC) (from SW V12)
Data interface, infrared (IrDA)
Optional:
Drive−based safety Safety option (SO) 10, 20 or 30
Operation in generator mode Internal or external brake resistor
Control element
Various service switches
Rocker switch
Operation
200 % overload current for 3 s
S ramps for jerk−free acceleration and
deceleration
Protection against restart for cyclic mains
switching
Technology applications
Speed actuating drive
Switch−off positioning
Absolute positioning
Table positioning
EMS−specific communication
Half wave
Half wave coded
Power wave
DECA BUS
Inductive energy transmission
PLC functionality

Table of Contents