Commissioning
Quick commissioning
Keypad control
8
145
EDS84DPS424 EN 5.0
4. Set keypad control
EDIT
Select CtrlMode
C00007
Quick commissioning
SAVE
Par1 Quick commissioning
Terminals
Keypad
SAVE
Par1 8400 StateLineC
User - Menu
Logbook
Go to param
Quick commissioning
EDIT
Load Lenze setting
C00002/1
Continue as in commissioning
step 3. Load Lenze setting to
controller:
"Quick commissioning" menu
Keypad
Load Lenze setting
Use the "down" navigation key to
go to code C00007 for selecting the
control mode:
Select parameter code 00007
and parameterise with "Edit"
Select value "20"− −> keypad and
confirm with "OK".
5. Enable controller:
8400 protec controllers are automatically enabled after mains connection. They
can also be enabled or inhibited via code C00002/16.
6. Vary the motor speed using the keypad or by defining different fixed setpoints:
Keypad Code Subcode Motor speed
EDIT
< ... >
C00728
C00051
SAVE
Par1 Quick commissioning
Terminals
Keypad
C00728 3 CCW rotation:
−199.99 % .... 0 (of C00011)
CW rotation:
0 .... +199.99 % (of C00011)
C00051 Display of actual speed
value
ƒ Please observe:
The actual speed value: C00051
7. Save the settings with in the keypad.