Technical data
General data and operating conditions
4
45
EDS84DPS424 EN 5.0
EMS version
Half−wave system
E84DE..., E84DL...
Control bar
Z system No
Number 2
Signal level
Full wave
Positive half wave
Negative half wave
Coded half wave
Reference voltage or switched
voltage
L3
L1 possible with different hardware configuration
Rated voltage
400−480 V AC, 50−60 Hz
Coded half wave: 230 V AC, 50−60 Hz
Switching threshold 50 Hz: 270 V AC (243 ... 297 V AC)
60 Hz: 330 V AC (297 ... 363 V AC)
Power input 1.5 W (400 V AC) for 1 x half wave
Signalling bar
Number 1
Signal level
Full wave
Positive half wave
Negative half wave
Reference voltage or switched
voltage
L3
L1 possible with different hardware configuration
Short circuit protection PTC protection (500 connected in series)
Reference voltage 400 ... 480 V
Switching current max. 28 mA AC