Index table
14
Appendix
14.2
l
14.2-4
EDSPM-TXXX-3.0-04/2004
Index ImportantPossible settingsName
SelectionLenze
I1403
h
Index is only a vailable in the modular
system
E 9.4-3
1 COB-ID used by
RxPDO 4
830 385 {1} 2047 Defining the individual identifie rs for
process da ta object 4
2 Transmisson type 255 0 {1} 255 Defining the transmission mode
0 Sync-controlled receive The input data are a ccepted on sync
telegram transmission.
1 ... 240 N-sync-controlled reception The input data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.
255 Event-controlled reception Every received value is accepted
I1404
h
Index is only a vailable in the modular
system
E 9.4-3
1 COB-ID used by
RxPDO 5
1024 385 {1} 2047 Defining the individual identifie rs for
process da ta object 5
2 Transmisson type 255 0 {1} 255 Defining the transmission mode
0 Sync-controlled receive The input data are a ccepted on sync
telegram transmission.
1 ... 240 N-sync-controlled reception The input data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.
255 Event-controlled reception Every received value is accepted
I1405
h
Index is only a vailable in the modular
system
E 9.4-3
1 COB-ID used by
RxPDO 6
1080 385 {1} 2047 Defining the individual identifie rs for
process da ta object 6
2 Transmisson type 255 0 {1} 255 Defining the transmission mode
0 Sync-controlled receive The input data are a ccepted on sync
telegram transmission.
1 ... 240 N-sync-controlled reception The input data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.
255 Event-controlled reception Every received value is accepted
I1406
h
Index is only a vailable in the modular
system
E 9.4-3
1 COB-ID used by
RxPDO 7
1152 385 {1} 2047 Defining the individual identifie rs for
process da ta object 7
2 Transmisson type 255 0 {1} 255 Defining the transmission mode
0 Sync-controlled receive The input data are a ccepted on sync
telegram transmission.
1 ... 240 N-sync-controlled reception The input data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.
255 Event-controlled reception Every received value is accepted
I1407
h
Index is only a vailable in the modular
system
E 9.4-3
1 COB-ID used by
RxPDO 8
1280 385 {1} 2047 Defining the individual identifie rs for
process da ta object 8
2 Transmisson type 255 0 {1} 255 Defining the transmission mode
0 Sync-controlled receive The input data are a ccepted on sync
telegram transmission.
1 ... 240 N-sync-controlled reception The input data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.
255 Event-controlled reception Every received value is accepted