EasyManua.ls Logo

Lenze L-force 8400 BaseLine D - Page 87

Lenze L-force 8400 BaseLine D
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 03.00 - DMS EN 5.0 - 07/2009 L 87
8400 BaseLine D | Software Manual
Motor control (MCTRL)
Selection of the operating mode
How to set the sensorless vector control:
1. Set code C6
to the value "4" for selecting the "sensorless vector control (SLVC)"
mode.
2. For the motor selection and parameterisation, the equivalent circuit data and the
nameplate data are required. Depending on the manufacturer of the motor used,
proceed as follows:
Lenze motor
Select the motor from the »Engineer« catalogue [A]
Carry out the motor parameter identification [C]
External motor
Enter the nameplate data of the motor [B]
and carry out the
motor parameter identification [C]
oder
directly enter nameplate data [D]
and known equivalent circuit data C084, C085
, C092
.