3-8 Service Manual
4060-xxx
Clearing the error log
1. Select Clear Log from the Error Log menu.
2. Select YES to clear the Error Log or NO to exit the Clear Log menu. If YES is selected, Empty
Error Log displays on the screen.
3. Press Return/Stop to exit the Clear Log menu.
Hardware tests
Select the following Hardware Tests from this menu:
LCD Test
Button Test
DRAM Memory Test
ROM Memory Test
Parallel Wrap (if available)
Serial Wrap (if available)
Serial 1 Wrap (if available)
Serial 3 Wrap (if available)
LCD Test
1. Select LCD Test from the Diagnostic menu. The LCD test continually executes the LCD display
test.
2. Press Return/Stop to cancel the test.
Button Test
1. Select Button Test from the Diagnostic menu. With no buttons pressed, several OP (Open)
appear on the display.
2. Press each button one at a time and a CL (Closed) displays in place of an OP. The proper
operation of each button can be checked.
3. Press Return/Stop to cancel the test.