4-28 Service Manual
4060-xxx
Fuser exit sensor or fuser narrow media sensor removal
1. Remove the fuser. See Fuser assembly removal” on page 4-23.
2. Cut the cable tie (A).
3. Unplug the sensor from the fuser control board.
4. Remove the sensor from the lower exit guide assembly.
Fuser lamp removal
1. Remove the fuser assembly. See “Fuser assembly removal” on page 4-23.
2. Disconnect the fuser lamp AC cable from the left side of the top cover assembly.
3. Remove the two screws (A) from the left side fuser lamp contact cover.
Warning: Take care when removing the screw, as the lamp is under spring tension. When the
contact is released, damage to the lamp or contact may occur.
A Exit SensorNarrow Media Sensor