Repair information 4-5
4060-xxx
Step B
Print a copy of the Quick Test Page and check the margin adjustments printed on the test page.
These settings should be within the range specified in “Print registration” on page 3-16. The
reference screw can be adjusted without loosening the locknut. Turn the screw a few turns and print a
copy of the Quick Test Page as you check the diamonds on the left margin. Continue adjusting the
screw as you check the results of each adjustment on a new test page until you obtain the results you
want.