Page 76 of 96
© 2020 LINAK A/S
Label for LA36
1. Type: 36120250A001BA-646G304500X0000
Describes the basic functionality of the product
2. Item no.: J06292
Sales and ordering code
3. Prod. Date: YYYY.MM.DD
Production date describes when the product has been produced. This date is the reference for warranty claims
4. Max Load: Push 4500N / Pull 4500N IP66
Describes the maximum load that the product can be exposed to in compression and tension.
This line also contains a reference to the product’s IP protection degree
5. Power Rate: 24VDC / Max. 13 Amp
Input voltage for the product and maximum current consumption
6. Duty Cycle: 20%, Max. 4 min. / 16 min.
The duty cycle defines the maximum period during operation without interruption. After operation, a pause
must be observed. It is important that the operator follows the instructions of the duty cycle; otherwise, a
possible overload may result in reduced product life/errors
7. W/O #1234567-0001
The LINAK work order followed by a unique sequential identification number