Page 77 of 96
© 2020 LINAK A/S
Label for LA36 IECEx/ATEX
1. Type.: 36xxxx+xxxxxx8x
Describes the basic functionality of the product.
2. Item no.: 36xxxx-xx
Sales and ordering code
3. Prod. Date.: YYYY.MM.DD
Production date describes when the product
has been produced. This date is the reference for
warranty claims.
4. Max Load.: Push xxxx N / Pull xxxxN IP66
Describes the maximum load that the product
can be exposed to in compression and tension.
This line also contains a reference to the
product’s IP protection degree
5. Power Rate.: XX V / Max. xx Amp
Input voltage for the product and maximum current
consumption
6. Duty Cycle.:
The duty cycle defines the maximum period
during operation without interruption. After
operation, a pause must be observed. It is
important that the operator follows the
instructions of the duty cycle; otherwise, a
possible overload may result in reduced product
life/errors
7. W/O #xxxxxxx
The LINAK work order followed by a unique
sequential identification number
* Not a source of ignition in normal operation or when subjected to faults that may be expected, though not on
a regular basis.
CE 0402 II 2D Ex tb IIIC T135°C Db Tamb -25°C to +65°C
*
Combustible dust - conductive
Quality assurance notification body
Equipment for hazardous areas
Non mining
Category 2 equipment for dust
Explosion protection
Protection by Enclosure
Temperature class
Enclosure Zone 21
Ambient temperature
of operation