Chapter 8 Built-in High-speed Counter Function
(e) Detail of comparator output
It describes detail of comparator output (based on comparator output 0)
1) Mode 0 (Present value < Compared value)
If counted present value is less than the minimum value of compared output 0, output
is sent out, and if present value increases to be equal to or greater than the minimum
value of compared output 0, output is not sent out.
2) Mode1 (Count value ≤ Compared value)
If present count value is less than or equal to the minimum set value of compared
output 0, output is sent out, and if count value increases to be greater than the
minimum set value of compared output 0, output is not sent out.
123456
123457
123458
123459
123460
123461
123462
123460
Count
value
Comp
ared
output 0
min. set value
Comp
ared output 0
Output Signal
Comp
ared
output 0
Enable
External output
(
in case of
designated output
)
Count value
Compared
output
0
Min. set value
Compared O
utput 0
output signal
Compared O
utput 0
Enable
External output
(
in case of
designated output)
123456
123457
123458
123459
123460
123461
123462
123460