Chapter 7 Input/Output Specifications
7.3.6 XEC-DP64H Output unit (Source type)
General output: 0.5A/1 point,
Output for positioning (%QX0.0.0 ~ %QX0.0.3): 0.1A/1 point, 2A/1COM
or less (Rated load, Resistive load)
4 point / COM (COM0~COM3), 8 point / COM (COM4~COM5)
Internal consumption
current
510 ㎃ (When all output are on)
External power
DC12/24V ± 10% (Ripple voltage 4 Vp-p or less)
or less (when connecting DC24V)
External connection method
42 point connecting connector (M3 X 6 screw)
TB2 PE
TB3
TB4 N
TB5 00
TB6 01
TB7 02
TB8 03
TB9
TB10 04
TB11 05
TB12 06
TB13 07
TB14 COM1
TB15 08
TB16 09
TB17 10
TB18 11
TB19
TB20 12
TB21 13
TB22 14
TB23 15
TB24 COM3
TB25 16
TB26 17
TB27 18
TB28 19
TB29 20
TB30 21
TB31 22
TB32 23
TB33
TB34 24
TB35 25
TB36 26
TB37 27
TB38 28
TB39 29
TB40 30
TB41 31
TB42 COM5