9.14 Fault detection On/O/Change value
Thellingprocesscanbecontrolledautomaticallybytheowmeter,sincefaultsmaydevelopinthecon-
necting lines, such as running dry, blockages, defective solenoid valves, etc.
Afterthestartofthellingprocess,theowmetermonitorsthetimeduringwhichnoliquidisregistered.
Theowmeterswitchesowhenacertaintimelimitisexceeded.Afaultreportappearsonthedisplay.
Theinterruptedllingprocesscanberesumedorcompletedwhenthefaulthasbeenremedied.
The monitoring time can be freely selected between 1 and 99999 seconds. A time of 3 seconds is set by
the manufacturer.
RM
Press "Change value" to change the duration of monitoring.
Press "On" to switch monitoring on.
This is the factory setting.
Press "O"toswitchmonitoringo.
Press "
C" to delete the last entry on the display.
Use the buttons "0-9" and "." to enter the monitoring time.
Press "Cncl" to cancel the entry and return to the previous screen.
Press "OK"tosavethedisplayedmonitoringtimeandnishmakingentries.
Fault detection
?
?
OK
Cancel
Change value
On Off
Monitoring time
3 s
Monitoring time
?
?
OK
Cncl
C1
2 3
654
7
8 9
0
Fault detection
?
?
OK
Cancel
Change value
On Off
Monitoring time
3 s
Menu
?
?
AUTO
START
Change
volume
Menu 3/5
?
?
Fault detection
Valve function
Leakage alarm
Overrun corr.
Ext. actuation