Operating mode Fault report Cause Remedy
Flow monitoring
On
Flow rate too low Pump damaged Check pump
Line strainer blocked Clean strainer
Hose line kinked Check hose line
Solenoid valve
damaged
Check solenoid valve
Flow monitoring
On
Flow rate too high Flow control valve
misaligned
Adjusttheowcontrolvalve
Volume preset No pulses Air in the piping
system/dry running
Prevent air pockets in
connecting lines, use a solid
hose system
Pump is not operating Check pump
Line strainer blocked Clean strainer
Time required to
lltheconnecting
lines exceeds the set
monitoring time
Increase monitoring time
Hose line kinked Check hose line
Solenoid valve
damaged
Check solenoid valve
The connection
between the modules
is interrupted
Check bus line
Basicowmeter
damaged
Checkbasicowmeter
Fuse in relay module
defective
Check fuses
Magnet or sensor
inbasicowmeter
damaged
Checkbasicowmeter
Volume preset /
Leakage alarm
On
Leakage in system Pipe or connections
not properly sealed
Check the pipe and
connections
Solenoid valve does
not close properly
Check solenoid valve
71
0698-651 Operating unit - 04/2021