EasyManuals Logo

Manitowoc Grove GRT9165 User Manual

Manitowoc Grove GRT9165
476 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #417 background imageLoading...
Page #417 background image
Grove Published 7-23-2020, Control # 668-02 6-15
GRT9165 OPERATOR MANUAL MAINTENANCE AND LUBRICATION
6
NOTE 11: Drain Transmission Fluid at a temperature of 65°C to 90°C (150°F to 200°F). Clean magnetic drain plug when
changing lubricant. Transmission and Torque Converter filter is located on the inside left side of the frame
behind the battery box.
NOTE 12: Follow these specified transmission fluid fill instructions:
a. Fill to FULL on DIPSTICK. Dipstick is located on the side of the carrier, adjacent to the hydraulic tank.
b. Run engine at 850 rpm to prime torque converter and lines.
c. Check fluid level with engine running at 850 rpm and torque converter fluid at 65°C to 90°C (150°F to 200°F).
d. Add transmission fluid, as necessary. FILL to FULL on DIPSTICK.
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Approximate
Capacity
Service Interval
Service
Application
CAUTION
Possible Equipment Damage!
Do not operate torque converter at stall condition for longer than 30 seconds at one time.
Shift to neutral for 15 seconds, and repeat procedure until desired fluid temperature
is reached.
Excessive fluid temperature [120°C (250°F) maximum] will damage transmission clutches,
transmission fluid, torque converter, and seals.
Failure to follow this instruction may cause damage to equipment.
FIGURE 6-2
9900-01
TOP VIEW OF CARRIER
FRONT
5a

Table of Contents

Other manuals for Manitowoc Grove GRT9165

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT9165 and is the answer not in the manual?

Manitowoc Grove GRT9165 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT9165
CategoryConstruction Equipment
LanguageEnglish

Related product manuals