MAINTENANCE AND LUBRICATION GRT9165 OPERATOR MANUAL
6-20 Published 7-23-2020, Control # 668-02
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Approximate
Capacity
Service Interval
Service
Application
Drive Train (Continued)
8
DEF Supply
Module Filter
Figure 6-5 — —
Every 4500 hours of
service, or 3 years,
whichever interval
comes first
CHECK DEF
Supply Module filter
9 Engine Oil Filter Figure 6-5 — — Every 500 hours
REPLACE engine
oil filter
See NOTE 15.
10
Driveline – Slip
Joints
Figure 6-5 A
Until grease
extrudes
Every 500 hours of
service, or 3 months,
whichever interval
comes first
LUBRICATE
3 grease fittings
See NOTE 17.
11 Fuel Filter Figure 6-5 — —
Every 500 hours of
service, or 6 months,
whichever interval
comes first
REPLACE fuel filter
See NOTE 16.
NOTE 15: The Engine Oil Filter is located on the lower inside left side of the frame adjacent to the torque converter.
NOTE 16: The Fuel Filter is located on the lower inside right side of the frame adjacent to the torque converter.
NOTE 17: DO NOT USE non semi-synthetic lubricant. Use of non-approved lubricant may damage components.
CAUTION
Possible Equipment Damage!
Use semi-synthetic or synthetic lubricants as listed in Section 6 of this Operator Manual. See
also your GRT9165 Service Manual for maintenance and lubrication instructions.
Use of non-approved lubricant may damage components and/or invalidate published
lubricant intervals.
Failure to follow this instruction may cause damage to equipment.